Short answer: Choose by installation constraints first, hazard second. Wall-mounted units suit tight, clean areas near a supply; pedestal units suit open plant floors; portable units cover sites without plumbing or as a supplement; combination shower units are required wherever full-body exposure is possible.
| Type | Best for | Main constraint | Maintenance load |
|---|---|---|---|
| Wall-mounted | Labs, corridors, small rooms with a nearby supply | Needs a structural wall and a short supply run | Low - weekly activation |
| Bench-top / desktop | Laboratory benches, teaching labs | Small coverage area, eyewash only | Low |
| Pedestal (floor-mounted) | Open plant floors, chemical processing, warehouses | Needs floor space, drainage and a supply leg | Low to medium |
| Portable / gravity-fed | Sites without plumbing, mobile plant, remote areas | Tank refill and fluid replacement cycle | High - fluid management |
| Combination shower and eyewash | Anywhere chemical splash or full-body exposure is possible | Large flow and drainage requirement | Medium |
1. Is full-body exposure possible? If yes, you need a combination shower unit. An eyewash alone does not cover a spill onto the torso, and no amount of eyewash capacity compensates.
2. Where is the nearest water supply? A wall-mounted unit is only cheaper if the supply is close. A 20 m branch to reach a convenient wall often costs more than a pedestal unit sited where the hazard is.
3. Can you drain it? A pedestal unit discharging onto a walkway creates a slip hazard and, in cold weather, an ice patch. Floor drainage or a containment arrangement belongs in the plan.
4. Can one person test it weekly? If the unit needs two people or a ladder to activate, the weekly check will lapse. This is a design criterion, not a discipline issue.
5. What is the climate? Outdoor or unheated installations need freeze protection - heat tracing, a heated enclosure or a drain-down design.
Wall-mounted in a corrosive area. The wall fixings and the valve body corrode before the bowl does. Specify 304 or 316 stainless steel for the whole wet path.
Pedestal unit with a high step. A pedestal with a deep foot plate or a raised base makes activation awkward and pushes the spray pattern out of the 33-53 inch band. Check the standing surface, not just the unit height.
Portable unit treated as a permanent station. A gravity-fed tank that nobody refills is worse than no station, because it creates a false sense of compliance. If you use portables, put them on the same log as plumbed units.
It can be the only unit where no plumbing exists, provided it delivers a 15-minute flush, is within 10 seconds of the hazard, and is maintained on a strict refill schedule. In most permanent facilities, a plumbed unit is the better answer.
If the quantities and hazards present could splash the body, yes. A risk assessment decides this, not the floor area.
For corrosive or hygienic environments, yes. For a dry, indoor, non-corrosive area, a coated carbon steel unit with a stainless bowl is a reasonable cost compromise - provided the coating is intact at every inspection.
One per hazard zone, positioned so the 10-second access rule is met from every point where a worker could be exposed. Large plants usually need more units than the headcount suggests.
Our range covers wall-mounted, pedestal, bench-top, portable and combination units. Send us a site layout with the hazard points marked and we will mark up a recommended configuration.
Sources: ANSI/ISEA Z358.1-2014 equipment definitions and installation requirements; CCOHS guidance on emergency shower and eyewash selection.